ΤΥΜΠΑΝΟΓΡΑΦΟΣ ΦΟΡΗΤΟΣ ΜΕ PRINTER MT10 INTERACOUSTICS
MT10 is an automatic, portable impedance audiometer for both screening and clinical applications . Main features:
– automatic Tympanometry test
– pass/fail limits on screen
– 4 acoustic reflex tests per ear
– actual reflex response is recorded
– reflexes tested at correct pressure
– automatic reflex search
– audiometric screening
– memory for 20 patients
– calculates gradient
– many printing options
– rechargeable batteries
– large high resolution display
Technical Specifications
? Tests – Tympanometry Normal: ? +200 to -300daPa ? Extended: +300 to -600daPa – Acoustic Reflex Test 4 reflexes per ear Automatic Intensity Search or Fixed Stimulus Intensity Intensities: up to 110 dBHL (l00 dBHL at 3-4 kHz) Frequencies: 0.5 kHz, 1 kHz, 2 kHz, 3 kHz, 4 kHz. Actual reflex recorded and displayed – ScreeningAudiometry Intensity: 10 dBHL to 50 dBHL Frequency: 0.5 kHz, 1 kHz, 2 kHz, 3 kHz, 4 kHz. ? Probe Tone – Frequency: 226 Hz ± 3% – Amplitude: 85 dB SPL ± 3 dB ? Pressure Direction of Sweep: – positive to negative – Pump Speed: 250 – 350 daPa/sec. – Resetting Time: 0 Seconds. – Pressure Accuracy: +/- 10% or 10daPa ? Internal Memory – Tympanometry, 4 reflex recordings and Audiogram for Left as well as Right ear. – 20 patients’ full testing scheme. – Selective patient storing. ? Power supply 3 High quality rechargeable NiMH batteries included. – Weight and Dimensions MT 10 Weight: 500 g – MT 10 Dimensions: 10 x 25 x 13 cm
Standard accessories
? Base station with built-in thermal printer, charging and interface to PC (only code 33646) ? 3 rolls of thermal paper ? Set of eartips ? Power supply: 3 NiMH rechargeable batteries ? Multilanguage operation manual (in 16 languages) ? Service manual
Description
MT10 is an automatic, portable impedance audiometer for both screening and clinical applications . Main features:
– automatic Tympanometry test
– pass/fail limits on screen
– 4 acoustic reflex tests per ear
– actual reflex response is recorded
– reflexes tested at correct pressure
– automatic reflex search
– audiometric screening
– memory for 20 patients
– calculates gradient
– many printing options
– rechargeable batteries
– large high resolution display
Technical Specifications
? Tests – Tympanometry Normal: ? +200 to -300daPa ? Extended: +300 to -600daPa – Acoustic Reflex Test 4 reflexes per ear Automatic Intensity Search or Fixed Stimulus Intensity Intensities: up to 110 dBHL (l00 dBHL at 3-4 kHz) Frequencies: 0.5 kHz, 1 kHz, 2 kHz, 3 kHz, 4 kHz. Actual reflex recorded and displayed – ScreeningAudiometry Intensity: 10 dBHL to 50 dBHL Frequency: 0.5 kHz, 1 kHz, 2 kHz, 3 kHz, 4 kHz. ? Probe Tone – Frequency: 226 Hz ± 3% – Amplitude: 85 dB SPL ± 3 dB ? Pressure Direction of Sweep: – positive to negative – Pump Speed: 250 – 350 daPa/sec. – Resetting Time: 0 Seconds. – Pressure Accuracy: +/- 10% or 10daPa ? Internal Memory – Tympanometry, 4 reflex recordings and Audiogram for Left as well as Right ear. – 20 patients’ full testing scheme. – Selective patient storing. ? Power supply 3 High quality rechargeable NiMH batteries included. – Weight and Dimensions MT 10 Weight: 500 g – MT 10 Dimensions: 10 x 25 x 13 cm
Standard accessories
? Base station with built-in thermal printer, charging and interface to PC (only code 33646) ? 3 rolls of thermal paper ? Set of eartips ? Power supply: 3 NiMH rechargeable batteries ? Multilanguage operation manual (in 16 languages) ? Service manual
Ειδικότητες Συνταγογράφησης:
Κωδικοί Παθήσεων:
Κωδικός Συνταγογράφησης: